Count | 1 pulse oximeter |
Includes | Pulse Oximeter, Lanyard, Carrying Case, 2 AAA Batteries, Instruction Manual |
Measuring Accuracy | 2% in stage 70%-100% SpO2 and meaningless when stage being smaller than 70%. 2% bpm or 2% (select larger) for Pulse Rate. |
Measuring Performance with Weak Filling Condition | SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is 4%, pulse rate is 2% bpm or 2% (select large) |
Optical Sensor | Red light (wavelength is 660nm, 6.65mW) Infrared (wavelength is 880nm, 6.75mW) |
Power Consumption | Smaller than 2.5 mA |
Power Requiredments | 2 x 1.5V AAA alkaline battery, adaptable range 2.6V-3.6V |
Pulse Intensity Display | Columniation Display |
Pulse Rate Measuring Range | 30 bpm - 250 bpm |
Resistance to Surrounding Light | The deviation between the value measured in the condition of man-made light, indoor natural light and that of a dark room is less than 1% |
Resolution | 1% for SpO2 and 1 bpm for Pulse Rate |
SpO2 Measuring Range | 0% - 100% |
Easy to operate |
Equipped with a Switch function. The Oximeter can be powered off when the finger is off the oximeter within 5 seconds |
High Accuracy |
Light and Compact |
Detailed Product Description
Specifications
Count | 1 pulse oximeter |
Includes | Pulse Oximeter, Lanyard, Carrying Case, 2 AAA Batteries, Instruction Manual |
Measuring Accuracy | 2% in stage 70%-100% SpO2 and meaningless when stage being smaller than 70%. 2% bpm or 2% (select larger) for Pulse Rate. |
Measuring Performance with Weak Filling Condition | SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is 4%, pulse rate is 2% bpm or 2% (select large) |
Optical Sensor | Red light (wavelength is 660nm, 6.65mW) Infrared (wavelength is 880nm, 6.75mW) |
Power Consumption | Smaller than 2.5 mA |
Power Requiredments | 2 x 1.5V AAA alkaline battery, adaptable range 2.6V-3.6V |
Pulse Intensity Display | Columniation Display |
Pulse Rate Measuring Range | 30 bpm - 250 bpm |
Resistance to Surrounding Light | The deviation between the value measured in the condition of man-made light, indoor natural light and that of a dark room is less than 1% |
Resolution | 1% for SpO2 and 1 bpm for Pulse Rate |
SpO2 Measuring Range | 0% - 100% |
Features
Easy to operate |
Equipped with a Switch function. The Oximeter can be powered off when the finger is off the oximeter within 5 seconds |
High Accuracy |
Light and Compact |